Electromagnetic flowmeters
For all applications with conductive liquids
- From basic to demanding flow measurements, incl. custody transfer and safety-related applications (up to SIL 2/3)
- Designs and liner materials for virtually any application – from potable water to extremely adhesive, abrasive and aggressive liquids
- Large choice of nominal sizes up to DN3000 / 120"
Electromagnetic flowmeter for safety instrumented systems (SIS) and high-accuracy requirements
- Certified for safety applications up to SIL 2/3, with automated partial proof test capability for extended proof test intervals
- Best-in-class diagnostic test interval incl. fault response time of only 2 minutes
- SIL 2/3 up to DN600 / 24"; non-SIL up to DN2000 / 80" (larger on request)
- Pulse, frequency, status, 4…20 mA, HART®7
Electromagnetic flowmeter for dosing systems, compact skids and wireless on-site verification
- Advanced flow measurement of liquids (≥5 μS/cm) with very high solid content
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- Various I/O, up to 3 x 4…20 mA HART®7; User-friendly parameterisation, monitoring and verification via Bluetooth® using the OPTICHECK Flow Mobile app
Electromagnetic flowmeter for advanced water and wastewater applications and wireless on-site verification
- Integrated conductivity measurement with fast response time for monitoring water quality issues and empty pipe events
- Advanced OPTICHECK technology built-in diagnostics and intuitive status indication via colour-coded backlit display
- Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
- Various I/O, up to 3 x 4…20 mA HART®7; User-friendly parameterisation, monitoring and verification via Bluetooth® using the OPTICHECK Flow Mobile app
Electromagnetic flowmeter for advanced water applications and wireless on-site verification
- High accuracy (±0.2%) flow measurement in freshwater distribution networks up to DN600 / 24"
- No straight inlet/outlet runs needed, suitable for use in disturbed flow conditions
- Advanced OPTICHECK technology built-in diagnostics and intuitive status indication via colour-coded backlit display, e.g. for conductivity monitoring or empty pipe alert
- Various I/O, up to 3 x 4…20 mA HART®7; User-friendly parameterisation, monitoring and verification via Bluetooth® using the OPTICHECK Flow Mobile app
Electromagnetic flowmeter for safety instrumented systems (SIS), advanced process applications and wireless on-site verification
- Certified for safety applications up to SIL 2/3; allows for automated partial proof tests providing extended proof test intervals
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
- Flange: DN2.5…3000 / ⅒…120", max. PN40 / ASME Cl 600 (higher on request)
- Various I/O, up to 3 x 4…20 mA HART®7; User-friendly parameterisation, monitoring and verification via Bluetooth® using the OPTICHECK Flow Mobile app
Electromagnetic flowmeter for advanced process applications, master metering and wireless on-site verification
- High accuracy meter (±0.15% of MV) with ceramic tube; suitable for aggressive and abrasive liquids and suspensions, incl. those with very high solid content and temperatures up to +180°C / +356°F
- Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
- Flange: DN15…300 / ½…12", max. PN40 / ASME Cl 300;
Sandwich: DN2.5...100 / ⅒...4" - Various I/O, up to 3 x 4…20 mA HART®7; User-friendly parameterisation, monitoring and verification via Bluetooth® using the OPTICHECK Flow Mobile app
Electromagnetic flowmeter for basic applications with conductive liquids
- Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
- Extra isolation of electronics for use in high humidity areas
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
Electromagnetic flowmeter for general applications with conductive liquids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
Electromagnetic flowmeter for OEM applications, dosing systems and compact skids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
Electromagnetic flowmeter for basic water and wastewater applications
- Liner materials resistant to low concentrated chemicals
- With extra isolation of electronics for use in high humidity areas
- Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
Electromagnetic flowmeter for all standard water and wastewater applications
- Chemically resistant liner materials
- Compact version up to IP69, remote version IP68
- Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
Electromagnetic flowmeter for utilities and industrial automation
- Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
- Best-in class temperature range, accuracy, pressure drop and flow range
- Ultra-compact design for parallel installation and tight spaces
- 4…20 mA, pulse, frequency, Modbus, IO-Link
Showing 12 of 37