SENSOFIT FLOW 1000 Y

Flow-through assembly for chemical and water treatment applications

  • For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
  • Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
  • For inline measurement at 180°Flow direction
  • Max. +95°C / +203°F and 10 bar / 145 psi

Related products

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation

Potentiometric ORP sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor

Conductive conductivity sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: G¾ (male)
  • 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
  • With stainless steel electrodes and Pt1000 for temperature compensation

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm

Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode and ceramic diaphragm

Conductive conductivity sensor for water, wastewater, process water or pure water

  • For use with analytical transmitter
  • Process connection: G½, G¾, G1, ¾ NPT (male)
  • 0.05 μS/cm…20 mS/cm; Max. +135°C / +275°F
  • With two stainless steel, titanium or graphite electrodes and Pt100 for temperature compensation

Potentiostatic amperometric disinfectant sensor for water and wastewater applications

  • For use with MAC 100 analytical transmitter
  • Process connection: PG13.5
  • Cl2: 0.03…20 mg/l; ClO2: 0.05…5  mg/l; O3: 0.05…5 mg/l; Max. +70°C / +158°F; 6 bar / 87 psi
  • Membrane-free sensor with 2 gold electrodes and sensor cleaning feature

KROHNE is a leading system provider in the field of industrial process measurement instrumentation. Employing over 4,000 people worldwide, KROHNE provides complete solutions for flow, level, pressure and temperature measurement, as well as for process analysis. In addition to these measurement devices, KROHNE offers commissioning, calibration and maintenance services.
The name KROHNE stands for innovation, reliability and high-quality products.

dev-ng.krohne.com