Cycle time of the internal diagnostics

Every SIL approved measuring device has an internal diagnostic routine that detects up to 95% of all possible faults in the device and, if necessary, reports them to the safety system by switching the device to the fault current.

Many devices of older development date still need 30 - 60 min for the internal diagnostics, i.e. in case of a malfunction of the safety function, the error would remain undetected for up to 60 min. In the meantime, the cycle time of the diagnostics could be reduced to 30 seconds to two minutes, so that these devices are even approved for the highest specified operating mode "Continuous Mode".

KROHNE is a leading system provider in the field of industrial process measurement instrumentation. Employing over 4,000 people worldwide, KROHNE provides complete solutions for flow, level, pressure and temperature measurement, as well as for process analysis. In addition to these measurement devices, KROHNE offers commissioning, calibration and maintenance services.
The name KROHNE stands for innovation, reliability and high-quality products.