SENSOFIT INS 1200

Insertion assembly with pressure indication and integrated safety features for analytical sensors

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors (pH, ORP etc.)
  • Integrated pressure test via "Quick'n'Safe" mechanism for safe, fast and comfortable removal and installation of sensors; enables sensor exchange without risk of glass breakage in <15 s
  • Sensor connection: PG13.5; Process connection: ¾ or 1 NPT, G¾
  • Max. +95°C / +203°F and 12 bar / 174 psi

Related products

Potentiometric pH sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation

Potentiometric pH sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation

Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation

Potentiometric pH sensor for food, beverage and pharmaceutical applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation

Potentiometric ORP sensor for chemicals and industrial wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor

Potentiometric ORP sensor for water and wastewater applications

  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode and ceramic diaphragm

KROHNE is a leading system provider in the field of industrial process measurement instrumentation. Employing over 4,000 people worldwide, KROHNE provides complete solutions for flow, level, pressure and temperature measurement, as well as for process analysis. In addition to these measurement devices, KROHNE offers commissioning, calibration and maintenance services.